Design Tools
Flexural Design of Isolated Footing
SQUARE FOOTING DESIGN · ACI 318-19
REINFORCED CONCRETE · FLEXURE · SHEAR · REBAR
Footing Size
—
B × L (ft)
Net Pressure
—
qu,net (ksf)
Punching Shear
—
Status
Beam Shear
—
Status
Steel Required
—
As,req (in²/ft)
Design Bar
—
@ spacing
Req. Spacing
—
c/c (calc)
Prov. Spacing
—
c/c (used)
Spacing Check
—
Req vs Prov
Design Summary
▾ click to collapse
▸ Footing Sizing
Surcharge Pressure—
Footing Self-Weight—
Avail. Bearing Press.—
Required Area—
Area Provided—
Width B—
Length L—
Net Pressure qu—
▸ Shear Design
Effective Depth d—
Critical Perimeter b₀—
Punch. Shear Vp—
Allow. Punch. Va—
Punching Check—
Beam Strip Length—
Beam Shear Vb—
Allow. Beam Va—
Beam Shear Check—
▸ Flexure Design
Moment Arm—
Design Moment Mu—
Rn—
ρ (Steel Ratio)—
ρ_max (εt≥0.004)—
ρ_max Check—
As,computed—
As,min—
As,T&S (Temp.)—
As,req (Governs)—
Controls—
Rebar Selection Table — All Standard Metric Bars
Run calculation to see rebar options.
Footing Diagram — Plan & Section View
Detailed Calculation — Engineering Report Format
🔒
Engineering Report — Password Protected
Enter password to view the detailed calculation report
✗ Incorrect password. Try again.
Press [RUN CALCULATION] to generate detailed engineering report.
Flexural strengthening of an interior reinforced concrete beam with FRP
CFRP Beam Retrofitting Calculator
ACI 440.2R-17 · Flexural Strengthening of RC Beams · Cross-Checked Against Example 16.3
US Customary
SI
ACI Notation: df = FRP soffit depth | ds = steel effective depth
P
Project Information
1
Beam Geometry
Width of beam, b
in
FRP Soffit Depth (Total Height), df = overall beam height; FRP bonded to soffit
in
Steel Effective Depth, ds = dist. from top fiber to steel centroid
in
Steel area, As
in²
2
Concrete & Steel Properties
Concrete strength, f'c
psi
Steel yield strength, fy
psi
3
CFRP System Properties
Ultimate tensile strength, f*fu
ksi
Elastic modulus, Ef
ksi
Rupture strain, ε*fu
in/in
No. of CFRP layers, ni
nos
Width of CFRP sheet, wf
in
Thickness per ply, tf
in
4
Applied Loading
Dead load moment, MDL
k-ft
Live load moment, MLL
k-ft
Factored design moment, Mu
k-ft
Assumed neutral axis depth, c (iterate until convergence)
in
Design Summary
—
Design Moment, Mu
—k-ft
Existing Capacity, φMn,exist
—k-ft
Retrofitted Capacity, φMn
—k-ft
—
Service Limit (1.1DL+0.75LL)
—k-ft
—
Steel Service Stress, fs,s
—ksi
—
FRP Creep Stress, ff,s
—ksi
—
CFRP Debond Strain, εfd
—
in/in
Development Length, Ldf
—in
📐 Beam Cross-Section & Strain Distribution
Concrete
Steel Bars (at ds)
CFRP Layer (at df)
Neutral Axis
Detailed Design Report — ACI 440.2R-17 (Cross-Checked vs. Example 16.3)
Report Access Required
Enter the password to view the Detailed Design Report.
✗ Incorrect password. Please try again.